; GSD-Datei: CP 1242-5 
; SIEMENS AG IIA SC IC
; File name : SI01818E.GSD
; File version : V1.0 
; Date: 08.10.2010
;=================================================================
#Profibus_DP
GSD_Revision = 5
Vendor_Name = "SIEMENS AG"
Model_Name = "CM 1242-5"
Revision = "V1"
Ident_Number = 0x818E
Protocol_Ident = 0
Station_Type = 0
FMS_supp = 0
Hardware_Release = "1"
Software_Release = "V1.0"
9.6_supp = 1
19.2_supp = 1
45.45_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp  = 1
6M_supp  = 1
12M_supp = 1
MaxTsdr_9.6 = 20
MaxTsdr_19.2 = 20
MaxTsdr_45.45 = 20
MaxTsdr_93.75 = 20
MaxTsdr_187.5 = 20
MaxTsdr_500 = 20
MaxTsdr_1.5M = 25
MaxTsdr_3M = 50
MaxTsdr_6M = 100
MaxTsdr_12M = 200
;
Repeater_Ctrl_Sig = 2
;Implementation_Type = "DPC31"
;Bitmap_Device  = "ASi8139n" ; todo
;Bitmap_Diag  = "ASi8139s"
;Bitmap_SF  = "ASi8139s"
;
OrderNumber = "6GK7 242-5DX30-0XE0" 
Info_Text = "CM 1242-5"
Freeze_Mode_supp = 1
Sync_Mode_supp  = 1
Auto_Baud_supp  = 1
Set_Slave_Add_supp = 0
Min_Slave_Intervall = 6 ; in 100us. base
Max_Diag_Data_Len = 128
Modul_Offset = 1
Slave_Family = 3@S7 1200
Fail_Safe    = 1
Modular_Station = 1
Max_Module = 32
Max_Input_Len = 240  
Max_Output_Len = 240 
Max_Data_Len = 480  
;
DPV1_Slave              = 1

;DPV1_Slave_required  = 1
C1_Read_Write_supp      = 1
C1_Max_Data_Len         = 240
C1_Response_Timeout   = 1000  ;max. Time for read/write (10ms Units)
C1_Read_Write_required  = 0   ;not required to be accessed
;DPV1_Data_Types         = 0  
Diagnostic_Alarm_supp   = 1
Alarm_Type_Mode_supp    = 1  
WD_Base_1ms_supp        = 1


C2_Read_Write_supp      = 1
C2_Max_Data_Len         = 240
C2_Response_Timeout   = 1000  ;max. Time for read/write (10ms Units)
C2_Max_Count_Channels   = 1
Max_Initiate_PDU_Length = 244

Ident_Maintenance_supp  = 1


;---------------------- Head Parameter -------------------------

Max_User_Prm_Data_Len = 237


; DPV1-Prm-Bytes 8-10
Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00



; <Module-Definition-List>

Module = "1 Byte Input"   0x40,0x80
1
EndModule
Module = "1 Byte Output"  0x80,0x80
2
EndModule
Module = "2 Byte Input"   0x40,0x81
3
EndModule
Module = "2 Byte Output"  0x80,0x81
4
EndModule
Module = "4 Byte Input"   0x40,0x83
5
EndModule
Module = "4 Byte Output"  0x80,0x83
6
EndModule
Module = "8 Byte Input"   0x40,0x87
7
EndModule
Module = "8 Byte Output"  0x80,0x87
8
EndModule
Module = "16 Byte Input"  0x40,0x8F
9
EndModule
Module = "16 Byte Output" 0x80,0x8F
10
EndModule
Module = "32 Byte Input"  0x40,0x9F
11
EndModule
Module = "32 Byte Output" 0x80,0x9F
12
EndModule
Module = "64 Byte Input"  0x40,0xBF
13
EndModule
Module = "64 Byte Output" 0x80,0xBF
14
EndModule

Module = "1 Word Input"   0x40,0xC0
15
EndModule
Module = "1 Word Output"  0x80,0xC0
16
EndModule
Module = "2 Word Input"   0x40,0xC1
17
EndModule
Module = "2 Word Output"  0x80,0xC1
18
EndModule
Module = "4 Word Input"   0x40,0xC3
19
EndModule
Module = "4 Word Output"  0x80,0xC3
20
EndModule
Module = "8 Word Input"   0x40,0xC7
21
EndModule
Module = "8 Word Output"  0x80,0xC7
22
EndModule
Module = "16 Word Input"  0x40,0xCF
23
EndModule
Module = "16 Word Output" 0x80,0xCF
24
EndModule
Module = "32 Word Input"  0x40,0xDF
25
EndModule
Module = "32 Word Output" 0x80,0xDF
26
EndModule
Module = "64 Word Input"  0x40,0xFF
27
EndModule
Module = "64 Word Output" 0x80,0xFF
28
EndModule