Rev 125 | Blame | Compare with Previous | Last modification | View Log | Download
createdAt: "2019-05-05T19:10:08.207Z"updatedAt: "2019-05-27T11:31:53.369Z"type: "MARKDOWN_NOTE"folder: "a254db85c99d975d1e63"title: "WP3 IBS"tags: []content: '''# WP3 IBS## PLC 1B1P2- [x] Uitgangs software PLC: 1B1P2_2019_05_02.FSS- [x] Laden SFS35, SFS36, SFS37 en SFS38- [x] Laden SFP35 en SFP36, header cyclic 1 sec.- [x] Invoeren SBR9- [x] Invoeren SBR250, oproep SFP35 INLINE = NO- [x] Invoeren SBR251- [x] Invoeren SBR252- [x] Oproep SBR250 met --||-- C500- [x] Oproep SBR251 met --||-- C500- [x] Oproep SBR252 met --||-- C500- [x] Importeren CCR commentaar- [x] Header text blocks laatste versie- [x] Compare Ladder programma, geen verschil met 1B1P2_2019_05_02_CCR.FSS. Compare resultaat in 1B1P2_20190506_compare.txt- [x] Backup PLC programma: 1B1P2_2019_05_08.FSS- [x] Level 2: PLC 1B1P2 'online' functioneert> 1B1P2_20190506_compare.txt> ```>Comparing Ladder:> No mismatches in Ladder>```## PLC 1B1P4- [x] Uitgangs software PLC: 1B1P4_20190429.FSS> Netwerk backup en actuele PLC software hebben 4 vergelijkings verschillen: netwerk 269, 284, 286 en 287.> Offline software gelijk gemaakt aan actuele PLC software op 06/05/2019.- [x] Geheugen indeling PLC aanpassen, Variable geheugen deel uitbreiden van 20kB naar **60kB**.>Op 06/05/2019 geconstateerd dat online PLC configuratie een variable geheugen ruimte heeft van 60kB. Offline backup is niet up to date!- [x] Laden SFS35, SFS36, SFS37 en SFS38- [x] Laden SFP35 en SFP36, header cyclic 1 sec.- [x] Invoeren SBR9- [x] Invoeren SBR250, oproep SFP35 INLINE = NO- [x] Invoeren SBR251- [x] Invoeren SBR252- [x] Oproep SBR250 met --||-- C500- [x] Oproep SBR251 met --||-- C500- [x] Oproep SBR252 met --||-- C500- [x] Importeren CCR commentaar- [x] Header text blocks laatste versie- [x] Compare Ladder programma, geen verschil met- [x] Backup PLC programma: 1B1P4_20190508.FSS- [x] Level 2: PLC 1B1P4 'online' functioneert> 1B1P4_20190506_compare.txt> ```>Comparing Ladder:> No mismatches in Ladder>```## PLC A01P1- [x] Uitgangs software PLC:- [x] Laden SFS35, SFS36, SFS37 en SFS38- [x] Laden SFP35 en SFP36> Geheugen op 07/05/2019 gewijzigd:> Ladder van 100kB naar 150 kB> > Special van 100kB naar 150 kB- [x] Invoeren SBR9- [x] Invoeren SBR250, oproep SFP35 INLINE = NO- [x] Invoeren SBR251- [x] Invoeren SBR252- [x] Oproep SBR250 met --||-- C500- [x] Oproep SBR251 met --||-- C500- [x] Oproep SBR252 met --||-- C500- [x] Importeren CCR commentaar- [x] Compare Ladder programma- [x] Backup PLC programma- [x] Level 2: PLC A01P1 'online' functioneert> A01P1_20190506_compare.txt> ```>Comparing Ladder:> No mismatches in Ladder>```## PLC A01P2- [x] Uitgangs software PLC:- [x] Laden SFS35, SFS36, SFS37 en SFS38- [x] Laden SFP35 en SFP36, header cyclic 1 sec.- [x] Invoeren SBR9- [x] Invoeren SBR250, oproep SFP35 INLINE = NO- [x] Invoeren SBR251- [x] Invoeren SBR252- [x] Oproep SBR250 met --||-- C500- [x] Oproep SBR251 met --||-- C500- [x] Oproep SBR252 met --||-- C500- [x] Importeren CCR commentaar- [x] Header text blocks laatste versie- [x] Compare Ladder programma- [x] Backup PLC programma- [x] Level 2: PLC A01P2 'online' functioneert> A01P2_20190506_compare.txt> ```>Comparing Ladder:> No mismatches in Ladder>```## PLC A02P6- [x] Uitgangs software PLC:- [x] Laden SFS35, SFS36, SFS37 en SFS38- [x] Laden SFP35 en SFP36, header cyclic 1 sec.- [x] Invoeren SBR9- [x] Invoeren SBR250, oproep SFP35 INLINE = NO- [x] Invoeren SBR251- [x] Invoeren SBR252- [x] Importeren CCR commentaar- [x] Oproep SBR250 met --||-- C500- [x] Oproep SBR251 met --||-- C500- [x] Oproep SBR252 met --||-- C500- [x] Header text blocks laatste versie- [x] Compare Ladder programma- [x] Backup PLC programma- [x] Level 2: PLC A02P6 'online' functioneert> A02P6_20190506_compare.txt> ```>Comparing Ladder:> No mismatches in Ladder>```'''linesHighlighted: []isStarred: falseisTrashed: false