Subversion Repositories rld.domoticz

Rev

Blame | Last modification | View Log | Download

<Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
  <MetaData>
    <MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/011A:0901:0601</MetaDataItem>
    <MetaDataItem name="ProductPic">images/enerwave/zwn-bpc.png</MetaDataItem>
    <MetaDataItem id="0901" name="ZWProductPage" type="0601">https://products.z-wavealliance.org/products/2165/</MetaDataItem>
    <MetaDataItem name="ResetDescription">3. Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all the module. Use  this  procedure only in the event that the network primary controller is missing or otherwise inoperable.</MetaDataItem>
    <MetaDataItem name="InclusionDescription">1. When the controller is in add mode, press and hold the program button of ZWN-BPC for 2 second, and then the controller will verify the add.</MetaDataItem>
    <MetaDataItem name="WakeupDescription">Once short press the program button  it will send  singlecast wake up notification to controller devices.</MetaDataItem>
    <MetaDataItem id="0901" name="FrequencyName" type="0601">U.S. / Canada / Mexico</MetaDataItem>
    <MetaDataItem name="Description">The PIR Motion Sensor ZWN-BPC is a Z-Wave enabled device and is fully compatible with other Z-Wave certified device from other manufacturers.  With the ZWN-BDS to monitor the  environment and provide hand-free lighting control, it can also trigger a Z-Wave enabled alarm when motion is detected and when there is movement within or across the detection of coverage, one triggering signal will be transmitted to all associated Z-Wave devices.</MetaDataItem>
    <MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/2165/20170111 ZWN-BPC.pdf</MetaDataItem>
    <MetaDataItem name="ExclusionDescription">2. When the controller is in remove mode, press and hold the program button of ZWN-BPC for 2 second, and then the controller will remove it from the current Z-Wave network.</MetaDataItem>
    <MetaDataItem id="0901" name="Identifier" type="0601">ZWN-BPC</MetaDataItem>
    <MetaDataItem name="Name">Ceiling Mounted PIR Motion Sensor</MetaDataItem>
    <ChangeLog>
      <Entry author="Justin Hammond - Justin@dynam.ac" date="02 Jun 2019" revision="3">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2165/xml</Entry>
    </ChangeLog>
  </MetaData>
  <CommandClass id="112">
    <Value genre="config" index="0" instance="1" label="Off time" max="255" min="0" size="1" type="byte" units="" value="0">
      <Help>Sets the time after triggering the sensor to send the Basic OFF command. 0: Don't send Basic OFF. 1-240: N minutes. 241-255: 15 seconds.</Help>
    </Value>
  </CommandClass>
  <CommandClass id="32">
    <Compatibility>
      <SetAsReport>true</SetAsReport>
    </Compatibility>
  </CommandClass>
  <CommandClass id="133">
    <Associations num_groups="1">
      <Group index="1" label="Reports" max_associations="5"/>
    </Associations>
  </CommandClass>
</Product>