; Copyright 2001-2005 Broadcom Corporation.
;
; INF for 64-bit AMD platform (Net server 2003).
;
; InfVersion   9.52.0.0.C
;
;*******************************************************************************
  
[Version]
Signature   = "$Windows NT$"
Class       = Net
ClassGUID   = {4d36e972-e325-11ce-bfc1-08002be10318}
CatalogFile = b57amd64.cat
Provider    = %BRCM%
DriverVer   = 05/15/2006,9.52.0.0


[Manufacturer]
%BRCM% = Broadcom, NTamd64


[ControlFlags]
ExcludeFromSelect = *

[Broadcom.NTamd64]
%BCM5700%      =  BCM5700CX.XpInst,   PCI\VEN_14e4&DEV_1644&REV_21
%BCM5700%      =  BCM5700CX.XpInst,   PCI\VEN_14e4&DEV_1644&REV_22
%BCM5700%      =  BCM5700.XpInst,     PCI\VEN_14e4&DEV_1644
%BCM5701%      =  BCM5701.XpInst,     PCI\VEN_14e4&DEV_1645
%BCM5702%      =  BCM5702.XpInst,     PCI\VEN_14e4&DEV_1646
%BCM5702%      =  BCM5702.XpInst,     PCI\VEN_14e4&DEV_16a6
%BCM5702%      =  BCM5702.XpInst,     PCI\VEN_14e4&DEV_16C6
%BCM5703%      =  BCM5703.XpInst,     PCI\VEN_14e4&DEV_1647
%BCM5703%      =  BCM5703.XpInst,     PCI\VEN_14e4&DEV_16a7
%BCM5703%      =  BCM5703.XpInst,     PCI\VEN_14e4&DEV_16C7
%BCM5704%      =  BCM5704.XpInst,     PCI\VEN_14e4&DEV_1648
%BCM5705%      =  BCM5705A2.XpInst,   PCI\VEN_14e4&DEV_1654
%BCM5705%      =  BCM5705A2.XpInst,   PCI\VEN_14e4&DEV_1654&SUBSYS_02D81014
%BCM5705%      =  BCM5705A2.XpInst,   PCI\VEN_14e4&DEV_1654&SUBSYS_02D91014
%BCM5705%      =  BCM5705.XpInst,     PCI\VEN_14e4&DEV_1653
%BCM5705FHPA%  =  BCM5705F.XpInst,    PCI\VEN_14e4&DEV_166e&SUBSYS_1700103c
%BCM5705FHPB%  =  BCM5705F.XpInst,    PCI\VEN_14e4&DEV_166e&SUBSYS_1703103c
%BCM5705M%     =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165E
%BCM5705M%     =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165E&SUBSYS_05721014
%BCM5705M%     =  BCM5705M.XpInst,    PCI\VEN_14e4&DEV_165D
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_0934103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_0938103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_0940103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_0944103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_0a0c103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_3095103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_3098103c
%BCM5750A1%    =  BCM5750A1M.XpInst,  PCI\VEN_14e4&DEV_167D&SUBSYS_3099103c
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1658
;%BCM5750A1%   =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1659
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1676
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167B
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167B&SUBSYS_2808103c
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167B&SUBSYS_280A103c
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167B&SUBSYS_280C103c
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167B&SUBSYS_2817103c
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_167C
%BCM5750A1%    =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_16F7
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_1658&REV_00
;%BCM5750%     =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_1659&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_1676&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_1677&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167C&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&SUBSYS_05771014&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&SUBSYS_0934103c&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&SUBSYS_0938103c&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&SUBSYS_0940103c&REV_00
%BCM5750%      =  BCM5750.XpInst,     PCI\VEN_14e4&DEV_167D&SUBSYS_0944103c&REV_00
%BCM5782%      =  BCM5705A2.XpInst,   PCI\VEN_14e4&DEV_1696
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_099c103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_308b103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_308e103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_3095103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_3098103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_3099103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_30b0103c
%BCM5788%      =  BCM5788.XpInst,     PCI\VEN_14e4&DEV_169C&SUBSYS_3021103c
%OEM3_DEV1%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_0890103c
%OEM3_DEV1%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_0a0c103c
%OEM3_DEV2%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_0894103c
%OEM3_DEV3%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_088c103c
%OEM3_DEV4%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_08bc103c
%OEM3_DEV4%    =  BCM5705MA2.XpInst,  PCI\VEN_14e4&DEV_165e&SUBSYS_099c103c
%OEM3_DEV5%    =  BCM5705F.XpInst,    PCI\VEN_14e4&DEV_166e&SUBSYS_3000103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3010103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3011103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3012103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3013103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3014103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3015103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1600&SUBSYS_3016103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_12f2103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3001103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3003103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3004103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3005103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3006103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3007103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3008103c
%OEM3_DEV6A1%  =  BCM5750A1.XpInst,   PCI\VEN_14e4&DEV_1677&SUBSYS_3009103c
%OEM3_DEV6%    =  BCM5751.XpInst,     PCI\VEN_14e4&DEV_1677&SUBSYS_3001103c&REV_00
%OEM3_DEV6%    =  BCM5751.XpInst,     PCI\VEN_14e4&DEV_1677&SUBSYS_3002103c&REV_00
%OEM3_DEV6%    =  BCM5751.XpInst,     PCI\VEN_14e4&DEV_1677&SUBSYS_3003103c&REV_00
%OEM3_DEV6%    =  BCM5751.XpInst,     PCI\VEN_14e4&DEV_1677&SUBSYS_3004103c&REV_00

;*******************************************************************************
; 64-bit Windows XP Install sections.
;*******************************************************************************

[BCM5700.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.WolS
AddReg          = Xp64AddReg, BCM5700.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOLNS
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5700.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5700.Xp64AddService, Xp64EventLog

[BCM5700.Xp64AddService]
DisplayName    = %BCM5700%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5700CX.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.WolS
AddReg          = Xp64AddReg, BCM5700.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOLNS, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5700CX.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5700CX.Xp64AddService, Xp64EventLog

[BCM5700CX.Xp64AddService]
DisplayName    = %BCM5700%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5701.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
AddReg          = Xp64AddReg, BCM5701.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOL, ParamsLgSnd, ParamsWireSpeed
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5701.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5701.Xp64AddService, Xp64EventLog

[BCM5701.Xp64AddService]
DisplayName    = %BCM5701%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5702.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
AddReg          = Xp64AddReg, BCM5702.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOL, ParamsLgSnd, ParamsWireSpeed
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5702.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5702.Xp64AddService, Xp64EventLog

[BCM5702.Xp64AddService]
DisplayName    = %BCM5702%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5703.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
AddReg          = Xp64AddReg, BCM5703.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOL, ParamsLgSnd, ParamsWireSpeed
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5703.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5703.Xp64AddService, Xp64EventLog

[BCM5703.Xp64AddService]
DisplayName    = %BCM5703%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5704.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.WolS
AddReg          = Xp64AddReg, BCM5704.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsJumbo, ParamsC, ParamsWOLNS, ParamsLgSnd, ParamsWireSpeed
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5704.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5704.Xp64AddService, Xp64EventLog

[BCM5704.Xp64AddService]
DisplayName    = %BCM5704%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5705.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5705.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL, ParamsWireSpeed, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5705.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5705.Xp64AddService, Xp64EventLog

[BCM5705.Xp64AddService]
DisplayName    = %BCM5705%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS

[BCM5705M.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5705M.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL, ParamsWireSpeed, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5705M.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5705M.Xp64AddService, Xp64EventLog

[BCM5705M.Xp64AddService]
DisplayName    = %BCM5705M%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5705F.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5705F.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC100, ParamsWOL, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5705F.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5705F.Xp64AddService, Xp64EventLog

[BCM5705F.Xp64AddService]
DisplayName    = %BCM5705F%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5705A2.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo, DelReg.WireSpeed
AddReg          = Xp64AddReg, BCM5705A2.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL,  ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5705A2.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5705A2.Xp64AddService, Xp64EventLog

[BCM5705A2.Xp64AddService]
DisplayName    = %BCM5705%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS

[BCM5705MA2.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo, DelReg.WireSpeed
AddReg          = Xp64AddReg, BCM5705MA2.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL,  ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5705MA2.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5705MA2.Xp64AddService, Xp64EventLog

[BCM5705MA2.Xp64AddService]
DisplayName    = %BCM5705M%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS


[BCM5788.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo, DelReg.WireSpeed
AddReg          = Xp64AddReg, BCM5788.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5788.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5788.Xp64AddService, Xp64EventLog

[BCM5788.Xp64AddService]
DisplayName    = %BCM5788%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS



[BCM5751.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo, DelReg.WireSpeed
AddReg          = Xp64AddReg, BCM5751.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL,  ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5751.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5751.Xp64AddService, Xp64EventLog

[BCM5751.Xp64AddService]
DisplayName    = %BCM5751%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS

[BCM5750.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5750.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOLShasta, ParamsWireSpeed, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5750.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5750.Xp64AddService, Xp64EventLog

[BCM5750.Xp64AddService]
DisplayName    = %BCM5750%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS



[BCM5750A1.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5750.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL, ParamsWireSpeed, ParamsLgSnd
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5750A1.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5750A1.Xp64AddService, Xp64EventLog

[BCM5750A1.Xp64AddService]
DisplayName    = %BCM5750%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS

[BCM5750A1M.XpInst.NTamd64]
Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL
DelReg          = DelReg.Jumbo
AddReg          = Xp64AddReg, BCM5750.Params, ParamsNt, ParamsNT8021p, ParamsNtW9x, ParamsC, ParamsWOL, ParamsWireSpeed, ParamsLgSnd, ParamsM
CopyFiles       = CopyFile.XpSys64
BusType         = 5

[BCM5750A1M.XpInst.NTamd64.Services]
AddService = b57nd, 2, BCM5750A1M.Xp64AddService, Xp64EventLog

[BCM5750A1M.Xp64AddService]
DisplayName    = %BCM5750%
ServiceType    = 1 
StartType      = 3
ErrorControl   = 1
ServiceBinary  = %12%\b57amd64.sys
LoadOrderGroup = NDIS




;*******************************************************************************
; 32-bit Windows Xp common sections.
;*******************************************************************************

[Xp64AddReg]
HKR, Ndi,            Service,    0, "b57nd"
HKR, Ndi\Interfaces, UpperRange, 0, "ndis5"
HKR, Ndi\Interfaces, LowerRange, 0, "ethernet"

[Xp64EventLog]
AddReg = Xp64AddEventLogReg

[Xp64AddEventLogReg]
HKR, , EventMessageFile, 0x00020000, "%%SystemRoot%%\System32\netevent.dll;%%SystemRoot%%\System32\drivers\b57amd64.sys"
HKR, , TypesSupported  , 0x00010001, 7



;*******************************************************************************
; Registry parameters.
;*******************************************************************************

[BCM5700.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "360"
HKR, , TxCoalescingTicks,        0, "360"
HKR, , RxMaxCoalescedFrames,     0, "15"
HKR, , TxMaxCoalescedFrames,     0, "75"


[BCM5701.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"


[BCM5702.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"


[BCM5703.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"


[BCM5704.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5705.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5705M.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5705F.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5705A2.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5705MA2.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5751.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"


[BCM5788.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[BCM5750.Params]
HKR, , TxPacketDescCnt,          0, "200"
HKR, , RxStdDescCnt,             0, "200"
HKR, , RxCoalescingTicks,        0, "10"
HKR, , TxCoalescingTicks,        0, "30"
HKR, , RxMaxCoalescedFrames,     0, "5"
HKR, , TxMaxCoalescedFrames,     0, "200"

[ParamsNt]
HKR, Ndi\Params\TaskOffloadCap,      ParamDesc, , %TaskOffload%
HKR, Ndi\Params\TaskOffloadCap,      default,   , "63"
HKR, Ndi\Params\TaskOffloadCap,      type,      , "enum"
HKR, Ndi\Params\TaskOffloadCap\enum, 0,         , %TaskOffload_None%
HKR, Ndi\Params\TaskOffloadCap\enum, 42,        , %TaskOffload_Rx_Chksum%
HKR, Ndi\Params\TaskOffloadCap\enum, 21,        , %TaskOffload_Tx_Chksum%
HKR, Ndi\Params\TaskOffloadCap\enum, 63,        , %TaskOffload_Rx_Tx_Chksum%

[ParamsNT8021p]
HKR, Ndi\Params\Enable8021p,      ParamDesc, , %QOS_8021p%
HKR, Ndi\Params\Enable8021p,      default,   , "0"
HKR, Ndi\Params\Enable8021p,      type,      , "enum"
HKR, Ndi\Params\Enable8021p\enum, 0,         , %QOS_8021p_Disable%
HKR, Ndi\Params\Enable8021p\enum, 1,         , %QOS_8021p_Enable%

[ParamsNtW9x]
HKR, Ndi\Params\FlowControlCap,      ParamDesc,  , %FlowControl%
HKR, Ndi\Params\FlowControlCap,      default,    , "2147483648"
HKR, Ndi\Params\FlowControlCap,      type,       , "enum"
HKR, Ndi\Params\FlowControlCap\enum, 0,          , %FlowControl_Disable%
HKR, Ndi\Params\FlowControlCap\enum, 1,          , %FlowControl_Rx_Pause%
HKR, Ndi\Params\FlowControlCap\enum, 2,          , %FlowControl_Tx_Pause%
HKR, Ndi\Params\FlowControlCap\enum, 3,          , %FlowControl_Rx_Tx_Pause%
HKR, Ndi\Params\FlowControlCap\enum, 2147483648, , %FlowControl_Auto%

HKR, Ndi\params\NetworkAddress,        ParamDesc,  0, %NetworkAddress%
HKR, Ndi\params\NetworkAddress,        Default,    0, ""
HKR, Ndi\params\NetworkAddress,        type,       0, "edit"
HKR, NDI\params\NetworkAddress,        LimitText,  0, "12"
HKR, NDI\params\NetworkAddress,        UpperCase,  0, "1"
HKR, NDI\params\NetworkAddress,        optional,   0, "1"

[ParamsJumbo]
HKR, Ndi\Params\RxMtu, ParamDesc, , %JumboMtu%
HKR, Ndi\Params\RxMtu, default,   , "1500"
HKR, Ndi\Params\RxMtu, type,      , "dword"
HKR, Ndi\Params\RxMtu, min,       , "1500"
HKR, Ndi\Params\RxMtu, max,       , "9000"
HKR, Ndi\Params\RxMtu, step,      , "500"
HKR, Ndi\Params\RxMtu, base,      , "10"

[ParamsWireSpeed]
HKR, Ndi\Params\WireSpeed,        ParamDesc, , %WireSpeed%
HKR, Ndi\Params\WireSpeed,        default,   , "1"
HKR, Ndi\Params\WireSpeed,        type,      , "enum"
HKR, Ndi\Params\WireSpeed\enum,   0,         , %WireSpeed_Disable%
HKR, Ndi\Params\WireSpeed\enum,   1,         , %WireSpeed_Enable%


[ParamsC]
HKR, Ndi\Params\RequestedMediaType,      ParamDesc, , %Speed_Duplex%
HKR, Ndi\Params\RequestedMediaType,      default,   , "0"
HKR, Ndi\Params\RequestedMediaType,      type,      , "enum"
HKR, Ndi\Params\RequestedMediaType\enum, 0,         , %Speed_Duplex_Auto%
HKR, Ndi\Params\RequestedMediaType\enum, 3,         , %Speed_Duplex_10Mb_Hd%
HKR, Ndi\Params\RequestedMediaType\enum, 4,         , %Speed_Duplex_10Mb_Fd%
HKR, Ndi\Params\RequestedMediaType\enum, 5,         , %Speed_Duplex_100Mb_Hd%
HKR, Ndi\Params\RequestedMediaType\enum, 6,         , %Speed_Duplex_100Mb_Fd%

[ParamsC100]
HKR, Ndi\Params\RequestedMediaType,      ParamDesc, , %Speed_Duplex%
HKR, Ndi\Params\RequestedMediaType,      default,   , "0"
HKR, Ndi\Params\RequestedMediaType,      type,      , "enum"
HKR, Ndi\Params\RequestedMediaType\enum, 0,         , %Speed_Duplex_Auto%
HKR, Ndi\Params\RequestedMediaType\enum, 3,         , %Speed_Duplex_10Mb_Hd%
HKR, Ndi\Params\RequestedMediaType\enum, 4,         , %Speed_Duplex_10Mb_Fd%
HKR, Ndi\Params\RequestedMediaType\enum, 5,         , %Speed_Duplex_100Mb_Hd%
HKR, Ndi\Params\RequestedMediaType\enum, 6,         , %Speed_Duplex_100Mb_Fd%


[ParamsWOL]
HKR, Ndi\Params\WakeUpModeCap,       ParamDesc, , %WakeUpMode%
HKR, Ndi\Params\WakeUpModeCap,       default,   , "3"
HKR, Ndi\Params\WakeUpModeCap,       type,      , "enum"
HKR, Ndi\Params\WakeUpModeCap\enum,  0,         , %WakeUpMode_None%
HKR, Ndi\Params\WakeUpModeCap\enum,  1,         , %WakeUpMode_Magic%
HKR, Ndi\Params\WakeUpModeCap\enum,  2,         , %WakeUpMode_Pattern%
HKR, Ndi\Params\WakeUpModeCap\enum,  3,         , %WakeUpMode_Both%

HKR, Ndi\Params\WolSpeed,       ParamDesc, , %WolSpeed%
HKR, Ndi\Params\WolSpeed,       default,   , "0"
HKR, Ndi\Params\WolSpeed,       type,      , "enum"
HKR, Ndi\Params\WolSpeed\enum,  0,         , %WolSpeed_Auto%
HKR, Ndi\Params\WolSpeed\enum,  1,         , %WolSpeed_10mb%
HKR, Ndi\Params\WolSpeed\enum,  2,         , %WolSpeed_100mb%

[ParamsWOLShasta]
HKR, Ndi\Params\WakeUpModeCap,       ParamDesc, , %WakeUpMode%
HKR, Ndi\Params\WakeUpModeCap,       default,   , "1"
HKR, Ndi\Params\WakeUpModeCap,       type,      , "enum"
HKR, Ndi\Params\WakeUpModeCap\enum,  0,         , %WakeUpMode_None%
HKR, Ndi\Params\WakeUpModeCap\enum,  1,         , %WakeUpMode_Magic%
; HKR, Ndi\Params\WakeUpModeCap\enum,  2,         , %WakeUpMode_Pattern%
; HKR, Ndi\Params\WakeUpModeCap\enum,  3,         , %WakeUpMode_Both%

HKR, Ndi\Params\WolSpeed,       ParamDesc, , %WolSpeed%
HKR, Ndi\Params\WolSpeed,       default,   , "0"
HKR, Ndi\Params\WolSpeed,       type,      , "enum"
HKR, Ndi\Params\WolSpeed\enum,  0,         , %WolSpeed_Auto%
HKR, Ndi\Params\WolSpeed\enum,  1,         , %WolSpeed_10mb%
HKR, Ndi\Params\WolSpeed\enum,  2,         , %WolSpeed_100mb%
; HKR, Ndi\Params\WolSpeed\enum,  2,         , %WolSpeed_1000mb%


[ParamsM]
HKR, , ClockControl,          0, "1"


[ParamsLgSnd]
HKR, Ndi\Params\LargeSendOffload,    ParamDesc, , %TaskOffload_LargeSend%
HKR, Ndi\Params\LargeSendOffload,    default,   , "1"
HKR, Ndi\Params\LargeSendOffload,      type,     , "enum"
HKR, Ndi\Params\LargeSendOffload\enum, 0,        , %TaskOffload_LargeSend_Disable%
HKR, Ndi\Params\LargeSendOffload\enum, 1,        , %TaskOffload_LargeSend_Enable%

[ParamsWOLNS]
HKR, Ndi\Params\WakeUpModeCap,       ParamDesc, , %WakeUpMode%
HKR, Ndi\Params\WakeUpModeCap,       default,   , "3"
HKR, Ndi\Params\WakeUpModeCap,       type,      , "enum"
HKR, Ndi\Params\WakeUpModeCap\enum,  0,         , %WakeUpMode_None%
HKR, Ndi\Params\WakeUpModeCap\enum,  1,         , %WakeUpMode_Magic%
HKR, Ndi\Params\WakeUpModeCap\enum,  2,         , %WakeUpMode_Pattern%
HKR, Ndi\Params\WakeUpModeCap\enum,  3,         , %WakeUpMode_Both%


;*******************************************************************************
; Keys to remove.
;*******************************************************************************

[DelReg.WolS]
HKR, Ndi\Params\WolSpeed

[DelReg.Jumbo]
HKR, Ndi\Params\RxMtu

[DelReg.WireSpeed]
HKR, Ndi\Params\WireSpeed

;*******************************************************************************
; Destination directories
;*******************************************************************************

[DestinationDirs]
DefaultDestDir   = 11
CopyFile.XpSys64 = 12

[SourceDisksNames]
1 = %DISK_DESC%,,,

[SourceDisksFiles]
b57amd64.sys = 1

[CopyFile.XpSys64]
b57amd64.sys,,,1



;*******************************************************************************
; Localizable strings
;*******************************************************************************

[Strings]
BRCM                = "Broadcom"
DISK_DESC           = "Broadcom NetXtreme Installation Media"

BCM5700             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5701             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5702             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5703             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5704             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5705             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5705M            = "Broadcom NetXtreme Gigabit Ethernet"
BCM5705F            = "Broadcom 570x 10/100 Integrated Controller"
BCM5901             = "Broadcom NetXtreme Fast Ethernet"
BCM5782             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5788             = "Broadcom NetLink (TM) Gigabit Ethernet"
BCM5789             = "Broadcom NetLink (TM) Gigabit Ethernet"
BCM5750             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5751             = "Broadcom NetXtreme Gigabit Ethernet"
BCM5750A1         = "Broadcom NetXtreme Gigabit Ethernet"
BCM5751A1         = "Broadcom NetXtreme Gigabit Ethernet"

BCM5700FB           = "Broadcom NetXtreme Gigabit Fiber"
BCM5700FA           = "Broadcom NetXtreme Gigabit Fiber"
BCM5701FA           = "Broadcom NetXtreme Gigabit Fiber"
BCM5703S            = "Broadcom NetXtreme Gigabit Fiber"
BCM5703SW           = "Broadcom NetXtreme Gigabit Fiber WOL"
BCM5704S            = "Broadcom NetXtreme Gigabit Fiber"

OEM2_DEV1           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV1           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV2           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV3           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV4           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV5           = "Broadcom 570x 10/100 Integrated Controller"
OEM3_DEV6           = "Broadcom NetXtreme Gigabit Ethernet"
OEM3_DEV6A1       = "Broadcom NetXtreme Gigabit Ethernet"

BCM5705FHPA            = "Broadcom NetXtreme FE-A"
BCM5705FHPB            = "Broadcom NetXtreme FE-B"


JumboMtu = "Jumbo Mtu"

FlowControl             = "Flow Control"
FlowControl_Disable     = "Disable"
FlowControl_Rx_Pause    = "Rx PAUSE"
FlowControl_Tx_Pause    = "Tx PAUSE"
FlowControl_Rx_Tx_Pause = "Rx/Tx PAUSE"
FlowControl_Auto        = "Auto"

Speed_Duplex          = "Speed & Duplex"
Speed_Duplex_Auto     = "Auto"
Speed_Duplex_10Mb_Hd  = "10 Mb Half"
Speed_Duplex_10Mb_Fd  = "10 Mb Full"
Speed_Duplex_100Mb_Hd = "100 Mb Half"
Speed_Duplex_100Mb_Fd = "100 Mb Full"
Speed_Duplex_1000Mb_Fd = "1000 Mb Full"

QOS_8021p         = "802.1p QOS"
QOS_8021p_Disable = "Disable"
QOS_8021p_Enable  = "Enable"

WireSpeed         = "Ethernet@WireSpeed"
WireSpeed_Disable = "Disable"
WireSpeed_Enable  = "Enable"

TaskOffload              = "Checksum Offload"
TaskOffload_None         = "None"
TaskOffload_Rx_Chksum    = "Rx TCP/IP Checksum"
TaskOffload_Tx_Chksum    = "Tx TCP/IP Checksum"
TaskOffload_Rx_Tx_Chksum = "Tx/Rx TCP/IP Checksum"

TaskOffload_LargeSend           = "Large Send Offload"
TaskOffload_LargeSend_Disable   = "Disable"
TaskOffload_LargeSend_Enable    = "Enable"

WakeUpMode         = "Wake Up Capabilities"
WakeUpMode_None    = "None"
WakeUpMode_Magic   = "Magic Packet"
WakeUpMode_Pattern = "Wake Up Frame"
WakeUpMode_Both    = "Both"

WolSpeed       = "WOL Speed"
WolSpeed_Auto  = "Auto"
WolSpeed_10mb  = "10 Mb"
WolSpeed_100mb = "100 Mb"
WolSpeed_1000mb = "1000 Mb"

NetworkAddress           = "Locally Administered Address"