Blame | Last modification | View Log | Download
Tecnomatix Nederland DECODER Task==========================================================================Copyright 2003 by Tecnomatix Nederland, The Netherlands.All rights reserved.FactoryLink is a registered trademark of United States Data Corporation,Richardson Texas USA.This file contains the following sections:InstallationFor more information:Tecnomatix NederlandHambakenwetering 15231 DD 's-HertogenboschThe Netherlandstel. + 31 73 640 0882fax + 31 73 644 0793==========================================================================***** Installation *****Installation of the FactoryLink software.First:Copy the files from the "Wizard ISO-TP4 ISO-TP4 driver" media tothe appropriate directories. This will be automatically done byrunning the setup utility placed on the installation media.Follow the next procedure:{goto your installation media and directory} eg.: e:\iso-tp4type: setup, followed by enterSecond:After you installed the software you need to activate the tables inthe FactoryLink Configuration Manager (FLCM). The installationautomatically appends the iso-tp4.ac entry into the {FLINK}/AC/titlesfile. The place of this entry is also the place where the optionappears in the FLCM Main Menu. Therefore check the validity of theentry and move it to the place where you want to appear it in theConfiguration manager. The entry must match the iso-tp4.ac entryin the following table:file: {FLINK}\ac\titles:...spool.acitimer.acetimer.acdecoder.aciso_tp4.actiway_1.ac...Third:To make sure all the Configuration Tables (CT's) are generated after achange, the install utility automatically adds the iso_tp4 entry at theend of the {FLINK}/ctgen/ctlist file. The place of this entry is notimportant. Check if this entry has the same format as in the next table:file: {FLINK}\ctgen\ctlist:...rp: rptovr rpthdriso_tp4: iso_tp4m iso_tp4x iso_tp4p iso_tp4dtimer: itimer etimer...Fourth:To enable the help fields in the Sinec H1 tables type the following command:{FLINK}\BIN\mkhelpFifth:The FactoryLink Configuration Manager uses a map file, {FLINK}/ac/ac2ct.map,to be aware of the different configuration tables which can be located behindone entry in the main menu. Upon startup, the Configuration Manager reads themap file instead of all the table configuration files, mainly because readingall these files at once takes too much time. An account manger is present toupdate this conversion file, and can be started from the command line.{FLINK}\BIN\acctmgr -c -dSixth:The iso_tp4 task must be entered in the FactoryLink Configuration Manager(FLCM) System Configuration table. An entry of an existing task which willnot be used at run-time can be overwritten or a new entry can be made withas a minimum the following data:Task Name Description .... Executable FileIOS_TP4 Wizard InfoSys ISO-TP4 driver bin/iso_tp4.exeThe Task Name and Executable File name are fixed and should not be alteredby the user.***** Installation *****==========================================================================Dataset configuration for device status info block:==========================================================================I/O Translator Tag DefinitionDomain Name : SHAREDTable Name : DEVICE1_______________________________________________________________________________Data Tag : Dev1NameDimension : 1Address : 0Bit or Length: 20Conv : MSGROWID : {7D97E6E7-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1TCPIPDimension : 1Address : 20Bit or Length: 20Conv : MSGROWID : {7D97E6E9-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1MACDimension : 1Address : 40Bit or Length: 15Conv : MSGROWID : {7D97E6EB-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1TypeDimension : 1Address : 55Bit or Length: 5Conv : MSGROWID : {7D97E6F9-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1FLINKDimension : 1Address : 60Bit or Length: 10Conv : MSGROWID : {7D97E6EF-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1TSAP[0]Dimension : 1Address : 70Bit or Length: 10Conv : MSGROWID : {7D97E6ED-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1TSAP[1]Dimension : 1Address : 80Bit or Length: 10Conv : MSGROWID : {7D97E6F7-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1TSAP[2]Dimension : 1Address : 90Bit or Length: 10Conv : MSGROWID : {7D97E6F5-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Connection[0]Dimension : 1Address : 100Bit or Length:Conv : BYTEROWID : {7D97E6F1-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Connection[1]Dimension : 1Address : 101Bit or Length:Conv : BYTEROWID : {7D97E701-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Connection[2]Dimension : 1Address : 102Bit or Length:Conv : BYTEROWID : {7D97E703-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Total[0]Dimension : 1Address : 110Bit or Length:Conv : WORDROWID : {7D97E6F3-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Total[1]Dimension : 1Address : 114Bit or Length:Conv : WORDROWID : {7D97E6FB-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Total[2]Dimension : 1Address : 118Bit or Length:Conv : LONGROWID : {7D97E6FD-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Time[0]Dimension : 1Address : 122Bit or Length:Conv : LONGROWID : {7D97E705-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Time[1]Dimension : 1Address : 126Bit or Length:Conv : LONGROWID : {7D97E709-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Time[2]Dimension : 1Address : 130Bit or Length:Conv : LONGROWID : {7D97E707-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Wait[0]Dimension : 1Address : 134Bit or Length:Conv : LONGROWID : {7D97E70B-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Wait[1]Dimension : 1Address : 138Bit or Length:Conv : LONGROWID : {7D97E70D-2FB9-11D7-ADCE-001122334455}_______________________________________________________________________________Data Tag : Dev1Wait[2]Dimension : 1Address : 142Bit or Length:Conv : LONGROWID : {7D97E70F-2FB9-11D7-ADCE-001122334455}