README.MODSOFT TCP/IP SETUP INSTRUCTIONSTHESE INSTRUCTIONS ARE APPLICABLE UNDER THE DOS/WINDOWS 3.X,WINDOWS 95 AND WINDOWS NT OPERATING SYSTEMS FOR ACCESS TO A PLCVIA TCP/IP(TRANSPORT CONTROL PROTOCOL/INTERNET PROTOCOL) OR VIA DECnet.NOTE:Please read and completely understand these instructions beforeinstallation. If a networking system administrator exists at yoursite, it is suggested that you have him/her review theseinstructions before proceding.IMPORTANT:Please see Sections B.1 and B.2 for install changes specificto DECnet.I. Quick Setup for WIN 95 and WIN NT:NOTE:-For setup under WIN 3.1 or inconsistencies in the quick setup with your system,refer to the detailed instructions in section III.-The quick setup assumes you installed Modsoft in the default C:\modsoftdirectoryA.) FOR WIN '95 SYSTEMS1) Edit the VSLDOS.INI file located in c:\modsoft\vsl.a) Go to the uncommented line TRANSPORT= ;Type in the <netkey>. Example: TRANSPORT=WINSOCKb) Go to the line that reads: NETMODULE=;Type in NETMODULE=JSBW95WSc) Save file.2) Copy the HOSTS.SAM file to HOSTS in the directory c:\windowsa) Go to the uncommented line in the HOSTS file that reads127.0.0.1 localhostb) Replace that line with:<IP_address of the machine> <your_IP_alias> localhostExample: 205.111.123.5 jdoe@inst.com localhostc) Save file3) Go to the directory C:\WINDOWS, and edit SYSTEM.INIa) Add a line under section [386Enh] that reads:DEVICE=C:\MODSOFT\VSL\JSBDOSWS.VXDb) Save file4) Go to the root directory and edit AUTOEXEC.BATa) Add line:SET VSL=C:\MODSOFT\VSLb) Save file5) Reboot the system.B.) FOR WIN NT SYSTEMS1) Edit the VSLDOS.INI file located in c:\modsoft\vsl.a) Go to the uncommented line TRANSPORT= ;Type in the <netkey>. Example: TRANSPORT=WINSOCKb) Go to the line that reads: NETMODULE=;Type in NETMODULE=JSBWNTWSc) Save file.2) Copy the HOSTS.SAM file to HOSTS in the directory C:\WINNTa) Go to the uncommented line in the HOSTS file that reads127.0.0.1 localhostb) Replace that line with:<IP_address of the machine> <your_IP_alias> localhostExample: 205.111.123.5 jdoe@inst.com localhostc) Save file3) Copy the HOSTS.SAM file to HOSTS in the directory \I386a) Go to the uncommented line in the HOSTS file that reads127.0.0.1 localhostb) Replace that line with:<IP_address of the machine> <your_IP_alias> localhostExample: 205.111.123.5 jdoe@inst.com localhostc) Save file4) Go to the file C:\WINNT\SYSTEM32\AUTOEXEC.NTa) Add 2 lines to this file: CD C:\MODSOFT\VSL and JSBDOSWS.EXEb) Save file5) Go to START buttona) Select SETTINGS->CONTROL PANEL, from the control panel selectthe SYSTEM icon.b) Select the TAB environmentc) There are two fields labelled VARIABLE and VALUEd) In the VARIABLE field, type VSLe) In the VALUE field, type C:\MODSOFT\VSLf) Click on SET and then OK6) Reboot the systemII. DETAILED OVERVIEWA.) Modsoft install for TCP/IP access to a programmablelogic controller.1) Under the DOS or Windows 3.x Operating Systems:install the DOS TSR (Terminate-and-Stay-Resident)based TCP/IP stack. (Note: Win95 already has a TCP/IPstack installed.)2) Install Modsoft from installation diskettes.3) Edit the vsldos.ini configuration file; forWin95 and Windows NT edit the hosts file and for Win95edit the \windows\system.ini file.4) Set the VSL environment variable.5) Load Network and Network Module (netmod) drivers.6) Using Modsoft with TCP/IP.B.) Modsoft installation changes for DECnet access to aprogrammable logic controller.1) Set the VSL environment variable.2) Load the DECnet Network Module (netmod).III. DETAILED INSTRUCTIONSA.1 INSTALLING THE DOS TSR BASED TCP/IP STACK.NOTE:For Win95 this step is NOT necessary.For Windows NT:Although a TCP/IP stack is deliverable with Windows NT, you must stillinstall a TSR for TCP/IP communications. The TSR is called jsbdosws.exeand is under the <modsoft_installation_directory>\vsl directory.It is recommended that you add the following lines to your autoexec.ntfile: cd <modsoft_installation_directory>\vsljsbdosws.exeThe autoexec.nt file is found under the<windows_nt_installation_directory>\system32 directory.You may also load the TSR at the DOS command line BUT YOU MUST BEin the <modsoft_installation_directory>\vsl directory when you load it.For DOS and Windows 3.1:Follow the stack-provider's install-instructions.Verify that the stack is installed correctly.Once the TCP/IP stack is installed, verify connectivity. To verifyIP-to-IP connectivity use the ping program. i.e.- ping <some_host>To verify TCP-to-TCP connectivity use a TCP application program liketelnet. i.e.- telnet <some_host>Modsoft 2.51 supports the following TCP/IP stacks:DOS TCP/IP STACK VSL NETWORK KEY(netkey)3Com 3+Open TCP v1.0, 1.1, 1.2, 2.0, 2.1 3openBeame and Whiteside TCP/IP v2.2, 2.3, 3.0 bwDigital Pathworks for DOS (TCP/IP) v4.1 decnetD-Link TCP/IP for DOS v2.0 locus2FTP PC/TCP v2.04, 2.05, 2.1 ftpFTP PC/TCP v2.2, 2.3 ftp22HP ARPA Services for DOS v2.1 3openIBM TCP/IP ibmtcpLocus TCP/IP for DOS v2.0 locus2Microsoft LAN Manager for MS-DOS (TCP/IP) v2.1 2.1a, 2.2 lanmanNovell LAN Workplace for DOS v4.0, 4.01, 4.1, 4.12 novlwpSun PC/NFS v3.0 pcnfsSun PC/NFS v3.5, 4.0a, 5.0, 5.1.5 pcnfs2Ungermann-Bass Net/One TCP/IP v16.4, 16.5, 16.6 netoneWalker Richer and Quinn Reflection Network Series v2.1 3openWollongong Pathway Access v1.1, 1.1.1, 1.1.2, 1.2, 2.0, 3.0 pathwayWollongong WIN/TCP for DOS v4.1.1 wintcpWindows 95 winsockWindows NT TCP/IP winsockA.2 INSTALL MODSOFT FROM INSTALLATION DISKETTES.Follow the install procedures outlined in the Modsoft ProgrammerUser Manual.A.3 EDIT THE VSLDOS.INI CONFIGURATION FILE, AND FOR WIN95/Windows NT,EDIT THE HOSTS FILE AND FOR WIN95 EDIT THE \WINDOWS\SYSTEM.INI FILES.The vsldos.ini file is located in the <modsoft_installation_directory>\VSLdirectory.Each supported TCP/IP stack has a VSL network module (netmod) andcorresponding netkey. Record that netkey in the vsldos.ini file,with your editor-of-choice.In the vsldos.ini file there is a heading entitled [vsl-default]. Thefirst uncommented line following this heading (commented lines beginwith a semi-colon) should read: transport=.After the edit of the former, the line should read: transport=<netkey>where <netkey> is the VSL network key that corresponds to the installedTCP/IP stack. For example, if Novell's Lan Workplace for DOS is the TCP/IPstack installed, then the first uncommented line following the [vsl-default]heading should read: transport=novlwp. Another example: if you are usingWin95 or Windows NT, then the first uncommented line followingthe [vsl-default] heading should read: transport=winsock.A list of netkeys is above in Section A.1, for your convenience, and alsoin the vsldos.ini file.For Windows NT: find the section of the vsldos.ini file that has the heading[winsock-transport]. Go to the line that reads: netmodule=. For Win95that line should read netmodule=JSBW95WS; for Windows NT it should readnetmodule=JSBWNTWS. Save the vsldos.ini file after you make the modification.For Win95 and Windows NT, copy the hosts.sam file (for Win95 the file isunder the \windows directory; for Windows NT it is under both the \i386and the <windows_nt_installation_directory>) to hosts. Replace the firstuncommented line in the file that reads: 127.0.0.1 localhost with<your_IP_address_in_dot_notation_form> <your_IP_alias> localhost.For example:84.31.1.1 jdoe@inst.com localhostFor Win95, add a line to the \windows\system.ini file under the[386Enh] section that reads:device=<modsoft_installation_directory>\vsl\jsbdosws.vxdNote: The computer will have to be rebooted to have that change takeeffect.A.4 SET THE VSL ENVIRONMENT VARIABLEModsoft 2.5 TCP/IP communications requires the setting of the VSLenvironment variable.It is suggested that this environment variable be set in your autoexec.batfile.Type: set VSL=<modsoft_installation_directory>\vslFor NT: go to Start button, select Settings->Control Panel->System.Select the TAB Environment. There are two fields labelled Variableand Value near the end of the tab screen.In the Variable field, type VSL.In the Value field, type drive:<modsoft_installation_directory\vslHelpful hint: If you have installed Novell's Lan Workplace for DOS (LWP),there is a barely-documented environment variable, EXCELAN, that is required.It must be set to the installation directory of the LWP software.A.5 LOAD NETWORK AND NETMOD DRIVERSNOTE: For Win95, this step is NOT necessary.For Windows NT, the netmod, jsbdosws.exe, is the only driver you must load.Although a TCP/IP stack is deliverable with Windows NT, youmust still install that TSR for TCP/IP communications. It is under the<modsoft_installation_directory>\vsl directory.It is recommended that you add the following lines to your autoexec.nt file:cd <modsoft_installation_directory>\vsljsbdosws.exeThe autoexec.nt file is found under the<windows_nt_installation_directory>\system32 directory.You may also load the TSR at the DOS command line BUT YOU MUST BEin the <modsoft_installation_directory>\vsl directory when you load it.(Note: the rest of this is not necessary for Windows NT.)Load all network drivers, in ISO-layered order.i.e.- physical, link, network, transport.Then load the network module (netmod).The netmod is located in the <modsoft_installation_directory>\vsl.Load it after the load of TCP/IP. Note: you do not have to load TCP/IPfor Windows NT. The netmod is an executable,with extension, .exe, with the same name as the network key BUTpreceded by the letter, m.For example: if you have installed Novell's Lan Workplace for DOS (LWP)the VSL network key (from above) is listed as, novlwp, thus the VSLnetwork module is mnovlwp.exe.To load the netmod change to the <modsoft_installation_directory>\vsl.Type: mnovlwp.Note: It is suggested that the load of all drivers take place in a batch file,that is invoked on power-up of your computer.An example follows, and assumes the LWP stack is installed:lh LSLlh 3C509lh IPXODIlh VLMlh TCPIPMNOVLWPA.6 USING MODSOFT WITH TCPIPTo access a controller via TCP/IP in Modsoft, select TCP/IP under Protocolfrom either the Offline|Change Plc Address sub-menu or theOnline|Direct to Plc sub-menu. (TCP/IP access is also available fromthe Utility|Quantum Backplane|Direct to Plc sub-menu and theUtility|PLC & IO Status|Direct to PLC sub-menu.)The Dest_Port should remain at 502, the default. The port, 502,is Schneider Automation's well-known TCP/IP port and wouldonly change if testing to a firewall.The Dest_Index should remain at 0, the default, unless you areusing Schneider's Modbus Plus to Ethernet bridge to talk betweena NOE and a MB+ node. A destination index of 0 accesses the PLCat Head 0.Input the IP address, symbolically or in dot notation, of the Network OptionsEthernet (NOE) module in the TCP/IP Address field. No broadcast/multicastIP address will be accepted.Note: the IP address (or the translated symbolic address) must agreewith the IP address in the configuration extension of the controller you wantto access. It is essential that the configuration extension be correctlyset-up in order to access the NOE module via TCP/IP. See the ModiconQuantum Ethernet TCP/IP Module User Guide for details. (part # 840 USE 107 00)B.1 SET THE VSL ENVIRONMENT VARIABLEThe virtual socket library (VSL) is used in Modsoft 2.5 (and beyond) toprovide access to a PLC via DECnet.The VSL requires the setting of the VSL environment variable.It is suggested that this environment variable be set in your autoexec.batfile.Type: set VSL=<modsoft_installation_directory>\vslB.2 LOAD THE DECnet NETWORK MODULE (netmod)Load all DECnet drivers.Then load the network module (netmod), mdecnet.exe.The netmod is located in the <modsoft_installation_directory>\vsl.To load the netmod change to the <modsoft_installation_directory>\vsl.Type: mdecnet.An examples follows, and assumes the load of the DECnet driversdelivered with BGAT:lh dllndislh netbindlh sch /hlh dnnethatmdecnetTRADEMARKS:DECnet is a Registered Trademark of Digital Equipment Corporation.Modsoft and BGAT (Base Gateway) are Registered Trademarks ofSchneider Automation, Inc.Win95, Windows NT and Windows 3.x are Registered Trademarks of the MicrosoftCorporation.DOS is a Registered Trademark.